Parr Instrument - page 53

1 - 8 0 0 - 8 7 2 - 7 7 2 0
6 7 5 0 P r o x i m a t e I n t e r f a c e
5
B u l l e t i n 6 7 5 0
Screenshot from the Proximate Interface showing Network Communications
Seamless Integration
The 6750 Proximate Interface
does not require a special
oven, furnace, or analytical
balance. All drying and ashing
operations are performed in
the same oven and furnace
normally used for standard
ASTM proximate analyses.
The 6750 Proximate Interface
can be installed in a variety of
configurations and the user
will want to choose the proper
installation procedures for his
or her planned setup.
Each 6750 Proximate Interface is
equipped with USB ports, two
SD card slots, and an Ethernet
network connection.
Normally, one USB connec-
tion will be used in conjunction
with a stand-alone printer. The
user has the ability to config-
ure parameters within the 6750
Proximate Interface to operate
with most existing printers. The
Parr 1758 Printer is a simple,
compact option if a stand-alone
printer is desired. A cable to
connect the 6750 Proximate
Interface to the 1758 Printer
is supplied with the printer.
Alternatively, the user may print
to a network printer using the
Ethernet connection.
The other USB port is used to
accept sample weights directly
from an analytical or top-loader
balance. The Interface allows
the user to choose from a wide
variety of standard balance
configurations or to establish
Contact our sales staff at
1-800-872-7720, for additional
information on the newest
member of the 6000 Series
instruments.
parameters specific to their
laboratory balance. Parr is able
to supply cables for common
balance connections.
An Ethernet network connec-
tion is used when the 6750
Proximate Interface will be
installed in conjunction with a
calorimeter and / or ADL orTotal
Moisture interface devices. Ad-
ditional 6750 Proximate Inter-
faces may be connected to the
network, configured as ADL or
Total Moisture interface devices
at some remote location. In
this system, the primary 6750
Proximate Interface can then be
configured to retrieve ADL or
Total Moisture weights from the
remote 6750 Proximate Inter-
face devices. If the 6750 Proxi-
mate Interface is connected to
a Parr Calorimeter via an Ether-
net communications network,
sample weights for heats of
combustion determinations will
be transferred automatically to
the calorimeter. Determined
BTU and Sulfur values can then
be transferred back to the 6750
Proximate Interface for incor-
poration in final reports. If the
6750 Proximate Interface is not
connected to a calorimeter con-
troller, BTU and Sulfur values
can be entered directly through
the touch screen. The 6750
Proximate Interface is compat-
ible solely with the line of 6000
Series instruments.
1...,43,44,45,46,47,48,49,50,51,52 54,55,56,57,58,59,60,61,62,63,...428