a remote Air Dry Loss, Total Moisture
Interface, or Balance Interface, accepting
data from a digital balance as generated;
organizing and storing it in the correct
order, under operator assigned sample
IDs. Several selectable options are avail-
able to speed the data entry process by
allowing the operator to enter consecutive
tare and gross weights automatically with
a minimum number of keystrokes.
The 6750 will calculate the resulting
proximate analysis for each sample on any
of four reference bases: As-Determined
(AD), As-Received (AR), Dry (DRY), or Dry,
Ash-Free (DAF). BTU and sulfur values
may be converted and reported based on
selected moisture references. The 6750
Proximate Interface supports data entry,
storage and reporting for Free Swelling
Index (FSI) and Ash Fusion along with the
more traditional mass loss or calorimetric
based measurements and will produce
final or preliminary reports at any time
for any sample ID.
Barcode Support Packages
Parr offers two complete packages that
can also be sold as individual compo-
nents for use with the Parr 6000 Series
instruments. The handheld scanner uses
CCD technology to scan codes on any flat,
curved or even damaged surfaces. The
scanner contains no moving parts liable
to wear, is built to withstand repeated
drops on a concrete floor, and comes with
a USB cable for simple connectivity.
1758 Printer
For users who prefer to have a dedicated
printer at the calorimeter, Parr offers the
model 1758 Printer. The 1758 Printer is
a compact, dot matrix printer setup for
40-column reports. It is 5.5 inches wide, 9
inches deep and 7 inches high and oper-
ates from its own power supply.
Oxygen Bomb Maintenance Kits
500 Firing Kits – One Year Supply
6004
For use w/ 1104B
6008
For use w/ 1108CL
6009A
For use w/ 1109A
6008P
For use w/ 1108PCL
6007
For use w/ 1107
6036
For use w/ A895DD (1136, 1138)
6038
For use w/ A1450DD (1136, 1138)
1758 Printer
Oxygen Bomb Repair Service
Oxygen Bombs should be returned on
a regular basis to Parr for general over-
haul and proof testing. There is a flat rate
charge (plus shipping) for the bomb ser-
vice. Each service includes:
• Disassembly, cleaning and inspection
of all bomb parts.
• Re-polishing inner surfaces of the
bomb cylinder and head.
• Re-assembly with new electrodes, elec-
trode insulators and seals, sealing rings
and valve seats, if needed to restore the
bomb to first class condition.
• Proof testing in accordance with
ASTM E144.
If the bomb head, screw cap, or cylin-
der must be replaced, they will be billed
at current parts prices. If the bomb cylin-
der is badly pitted or corroded and must
be re-bored, there will be an additional
charge. Any additional labor required
to repair or restore the bomb to usable
condition will be billed at current labor
cost. Repairs for all other bombs will be
charged on a time and materials basis.