Parr Instrument - page 25

6100 Calorimeter open with 1108P Bomb and Bucket
S P E C I F I C A T I O N S
Model Number:
6100
Tests Per Hour:
4 – 7
Operator Time Per Test:
6 Minutes
Precision Classification:
0.1 – 0.2% Class
Jacket Type:
Continuously Compensated
Oxygen Fill:
Automatic
Bucket Fill:
Manual
Bomb Wash:
Manual
Bomb Model Options:
1108, Alloy 20
1108CL, Alloy G30
1108B, Alloy 20
1108BCL, Alloy G30
1108BP, Alloy 20
1108BPCL, Alloy G30
1108P, Alloy 20
1108PCL, Alloy G30
1109A, 22mL Semi-micro Bomb
1104, High Strength Bomb
Balance Communication:
USB
Printer Communication:
USB
Network Connection:
TCP/IP via Ethernet
Dimensions (cm):
57w x 40d x 43h
T
he 6100 Continuously
Compensated Calorimeter
is a
compact, static jacket calorimeter that
operates at approximately room tem-
perature taking full advantage of modern
microprocessor capabilities. The micro-
processor controller in the 6100 will auto-
matically monitor the jacket temperature
and apply the required corrections in
real time. The advantages of this sys-
tem include less water, less energy, and
less hardware while still affording good
precision. The 6100 model also uses the
traditional removable bomb and bucket
design. This combination along with a
reasonable price makes it attractive for
coal testing, waste and refuse disposal
work, and other sample testing.
Automatic Oxygen Fill
Like the 6200 Calorimeter, the 6100
Calorimeter has an automatic system for
charging the bomb with oxygen where
the oxygen feed is controlled by a sole-
noid installed inside the calorimeter. To
fill the bomb, the operator simply slips
the filling hose connector onto the bomb
inlet valve and presses a button on the
touch screen to start the filling sequence.
Filling then proceeds automatically at a
controlled rate to an established operating
pressure.
Good Repeatability
With careful control of the testing environ-
ment, and a routine calibration schedule,
the Parr 6100 Compensated Calorimeter
with it’s static jacket can acheive a preci-
sion classification of 0.1%. Please see our
website, or refer to the operator’s manual
for more details.
Laboratory Requirements
The calorimeter requires a source of 99.5%
oxygen, and deionized water for operation.
Expanded System
The 6120 Expanded System includes
the following components:
• 6100 Calorimeter
• 1758 Printer
• Extra Bomb and Bucket
• 6008P Bomb Maintenance Kit
• 6109P, 1 Year Service Kit
6100 Ordering Guide
6100 Compensated Jacket Calorimeter
Model No.
Voltage
Description
6100EA / EF
115 V / 230 V
6100 Calorimeter with 1108P Oxygen Bomb of Alloy 20
6100CLEA / EF 115 V / 230 V
6100 Calorimeter with 1108PCL Oxygen Bomb of Alloy G30
6120EA / EF
115 V / 230 V
6120 Expanded System with 1108P Oxygen Bomb of Alloy 20 and Principal Components
6120CLEA / EF 115 V / 230 V
6120 Expanded System with 1108PCL Oxygen Bomb of Alloy G30 and Principal Components
6100 Compensated Calorimeter
O x y g e n C o m b u s t i o n C a l o r i m e t e r s
B u l l e t i n 6 0 0 0
13
1 - 8 0 0 - 8 7 2 - 7 7 2 0
1...,15,16,17,18,19,20,21,22,23,24 26,27,28,29,30,31,32,33,34,35,...428
Powered by FlippingBook