6772 Calorimetric Thermometer
S P E C I F I C A T I O N S
Model Number:
6772
Operating Range:
10 - 50 °C
Resolution:
0.0001 °C
Absolute Accuracy w/out Calibration:
± 0.100 °C
Absolute Accuracy w/ Calibration:
± 0.0500 °C
Repeatability, Single Point:
± 0.002 °C
Linearity, 10 °C Span:
± 0.002 °C
Balance Communication:
USB
Printer Communication:
USB
Network Connection:
TCP/IP via Ethernet
Dimensions (cm):
56w x 36d x 31h
T
he 6772 Calorimetric
Thermometer
is a high precision
temperature measuring system based
upon the control systems of the 6000
Series Calorimeters. It is an integral
part of the 6725 Semi-micro Calorimeter
and the 6755 Solution Calorimeter.
Additionally, the 6772 is able to provide
automatic control and communication
capabilities to the 1341 Plain Jacket
Calorimeter.
Microprocessor Design
The 6772 Thermometer has the ability
to collect data from two thermistors and
comes with one thermistor standard. The
microprocessor, central to the function of
the unit, is able to linearize the tempera-
ture signal and provide excellent resolution
and precise repeatability over each operat-
ing range.
Test Automation
In addition to measuring temperatures,
the 6772 Thermometer will determine the
net temperature rise, apply all necessary
corrections, and calculate and report the
heat of combustion in the associated
calorimeter as selected by the operator.
Data Collection
The addition of the 6772 to a calorimetric
system will allow the user to print to an
attached printer, obtain weights from a
balance, and transfer data to a computer.
Any data collected may be sent to a
connected printer. This printer may be
connected directly through the USB port
located in the back of the thermometer
or the printer may be on the laboratory
network.
The 6772 supports input from multiple
balance types. Additionally, a generic
input driver is provided for communica-
tions with balances that do not conform
to the eight supported protocols. This
communication is through the USB port
on the back of the thermometer.
The 6772 Calorimetric Thermometer
can function as a data logger, collecting
data as the test proceeds, and transferring
the data in CSV format. Alternatively, data
may be collected internally and displayed
or printed as a final report. Test data can
be transferred to an Ethernet network con-
nected computer using the FTP File Trans-
fer Protocol. Test reports may also be
viewed and printed with a web browser.
6772 Ordering Guide
6772 Calorimetric Thermometer
Model No.
Voltage
Description
6772EA / EF
115 V / 230 V
6772 Calorimetric Thermometer
1168E2
NA
Thermistor Probe
6772 Calorimetric Thermometer
O x y g e n C o m b u s t i o n C a l o r i m e t e r s
B u l l e t i n 6 0 0 0
15
1 - 8 0 0 - 8 7 2 - 7 7 2 0